1.
Rev Bras Ortop (Sao Paulo) ; 57(6): 968-974, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36540742

RESUMEN

Objective The present study aims to evaluate the influence of different positioning of the hip femoral prosthesis on the stress and strain over this implant. Methods A femoral prosthesis (Taper - Víncula, Rio Claro, SP, Brazil) was submitted to a stress and strain analysis using the finite element method (FEM) according to the International Organization for Standardization (ISO) 7206-6 Implants for surgery - Partial and total hip joint prostheses - Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components standard. The analysis proposed a branch of the physical test with a +/- 5° angle variation on the standard proposed for α and ß variables. Results The isolated +/- 5° variation on the α angle, as well as the association of +/- 5° variation on the α and ß angles, presented significant statistical differences compared with the control strain ( p = 0.027 and 0.021, respectively). Variation on angle ß alone did not result in a significant change in the strain of the prosthesis ( p = 0.128). The stem positioning with greatest implant strain was α = 5° and ß = 14° ( p = 0.032). Conclusion A variation on the positioning of the prosthetic femoral stem by +/- 5° in the coronal plane and/or the association of a +/- 5° angle in coronal and sagittal planes significantly influenced implant strain.

2.
Acta Ortop Bras ; 30(5): e255298, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36451792

RESUMEN

Objective: To evaluate the impact of the COVID-19 pandemic on hospital admission and mortality indicators in older adults with fractures of the proximal femur. Methods: Observational and retrospective study that took place from June 2016 to 2020. Patients of both genders who underwent surgical treatment for fractures of the proximal end of the femur, aged over 60 years, were included. Results: The population consisted of 379 patients, treated before (group 1; N = 278; 73.35%) and during the pandemic (group 2; N = 101; 26.65%). Higher mortality was observed in group 2 (N = 24; 23.8%) versus group 1 (N = 10; 3.6%), p < 0.001. The highest proportion of deaths in group 2 was maintained in patients aged 70-79 years (p = 0.011), 80-89 years (p ≤ 0.001) and > 90 years (p ≤ 0.001). In addition, the preoperative time and hospital stay were longer in group 2 compared to group 1 (p ≤ 0.001). Conclusion: The present study demonstrated that the pandemic period increased the mortality rate and the preoperative and hospitalization time in older patients with femur fractures. Thus, the pandemic has affected the care of fractures of the proximal femur in older adults, which reinforces the need to adopt measures to reduce complications and mortality. Level of Evidence II, Retrospective Study.


Objetivo: Avaliar o impacto da pandemia de COVID-19 nos indicadores de internação e mortalidade hospitalar em idosos com fraturas do fêmur proximal. Métodos: Estudo observacional e retrospectivo, que ocorreu de junho de 2016 a 2020. Foram incluídos pacientes de ambos os sexos submetidos ao tratamento cirúrgico para fratura da extremidade proximal do fêmur, com idade acima de 60 anos. Resultados: A população foi composta por 379 pacientes, atendidos antes (grupo 1; N = 278; 73,35%) e durante a pandemia (grupo 2; N = 101; 26,65%). Foi verificada maior mortalidade no grupo 2 (N = 24; 23,8%) versus o grupo 1 (N = 10; 3,6%), p < 0,001. A maior proporção de óbitos no grupo 2 se manteve nos pacientes com 70-79 anos (p = 0,011), 80-89 anos (p ≤ 0,001) e > 90 anos (p ≤ 0,001). Os períodos pré-operatório e de permanência hospitalar foram maiores no grupo 2 em comparação ao grupo 1 (p ≤ 0,001). Conclusão: Este estudo demonstrou que o período pandêmico aumentou a taxa de mortalidade e o tempo pré-operatório e de internação em pacientes idosos com fratura do fêmur. Dessa forma, a pandemia tem afetado o atendimento das fraturas do fêmur proximal em idosos, o que reforça a necessidade da adoção de medidas de redução de complicações e mortalidade. Nível de Evidência II, Estudo Retrospectivo.

3.
Rev. bras. ortop ; 57(6): 968-974, Nov.-Dec. 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1423630

RESUMEN

Abstract Objective The present study aims to evaluate the influence of different positioning of the hip femoral prosthesis on the stress and strain over this implant. Methods A femoral prosthesis (Taper - Víncula, Rio Claro, SP, Brazil) was submitted to a stress and strain analysis using the finite element method (FEM) according to the International Organization for Standardization (ISO) 7206-6 Implants for surgery - Partial and total hip joint prostheses - Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components standard. The analysis proposed a branch of the physical test with a +/− 5° angle variation on the standard proposed for α and β variables. Results The isolated +/− 5° variation on the α angle, as well as the association of +/− 5° variation on the α and β angles, presented significant statistical differences compared with the control strain (p= 0.027 and 0.021, respectively). Variation on angle β alone did not result in a significant change in the strain of the prosthesis (p= 0.128). The stem positioning with greatest implant strain was α = 5° and β = 14° (p= 0.032). Conclusion A variation on the positioning of the prosthetic femoral stem by +/− 5° in the coronal plane and/or the association of a +/− 5° angle in coronal and sagittal planes significantly influenced implant strain.


Resumo Objetivo Avaliar a influência da variação do posicionamento da prótese femoral do quadril na tensão e na deformação produzidas neste implante. Métodos Utilizou-se a análise de tensão e de deformação da prótese femoral (Taper, Víncula, Rio Claro, SP, Brasil) pelo método de elementos finitos (MEF) de acordo com a norma ISO 7206-6 Implants for surgery - Partial and total hip joint prostheses-Part 6: Endurance properties testing and performance requirements of neck region of stemmed femoral components. A análise propôs uma ramificação do ensaio físico, com variação da angulação de +/− 5° sobre a proposta normativa das variáveis α e β. Resultados Ao comparar com a deformação controle, houve significância estatística com a angulação isolada de +/− 5° do ângulo α, bem como com a associação de +/− 5° nas angulações α e β (p= 0,027 e 0,021, respectivamente). Já com a variação apenas do ângulo β, não houve variação significativa na deformação da prótese (p= 0,128). A posição da haste com maior deformação no implante foi com α = 5° e β = 14° (p= 0,032). Conclusão A variabilidade de posicionamento da haste femoral protética de +/− 5° no plano coronal e/ou a associação da angulação de +/− 5° nos planos coronal e sagital interferiu de forma significativa na deformação do implante.


Asunto(s)
Humanos , Análisis de Falla de Equipo , Artroplastia de Reemplazo de Cadera/efectos adversos , Análisis de Elementos Finitos , Prótesis de Cadera
4.
Acta ortop. bras ; 30(5): e255298, 2022. tab
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1403042

RESUMEN

ABSTRACT Objective: To evaluate the impact of the COVID-19 pandemic on hospital admission and mortality indicators in older adults with fractures of the proximal femur. Methods: Observational and retrospective study that took place from June 2016 to 2020. Patients of both genders who underwent surgical treatment for fractures of the proximal end of the femur, aged over 60 years, were included. Results: The population consisted of 379 patients, treated before (group 1; N = 278; 73.35%) and during the pandemic (group 2; N = 101; 26.65%). Higher mortality was observed in group 2 (N = 24; 23.8%) versus group 1 (N = 10; 3.6%), p < 0.001. The highest proportion of deaths in group 2 was maintained in patients aged 70-79 years (p = 0.011), 80-89 years (p ≤ 0.001) and > 90 years (p ≤ 0.001). In addition, the preoperative time and hospital stay were longer in group 2 compared to group 1 (p ≤ 0.001). Conclusion: The present study demonstrated that the pandemic period increased the mortality rate and the preoperative and hospitalization time in older patients with femur fractures. Thus, the pandemic has affected the care of fractures of the proximal femur in older adults, which reinforces the need to adopt measures to reduce complications and mortality. Level of Evidence II, Retrospective Study.


RESUMO Objetivo: Avaliar o impacto da pandemia de COVID-19 nos indicadores de internação e mortalidade hospitalar em idosos com fraturas do fêmur proximal. Métodos: Estudo observacional e retrospectivo, que ocorreu de junho de 2016 a 2020. Foram incluídos pacientes de ambos os sexos submetidos ao tratamento cirúrgico para fratura da extremidade proximal do fêmur, com idade acima de 60 anos. Resultados: A população foi composta por 379 pacientes, atendidos antes (grupo 1; N = 278; 73,35%) e durante a pandemia (grupo 2; N = 101; 26,65%). Foi verificada maior mortalidade no grupo 2 (N = 24; 23,8%) versus o grupo 1 (N = 10; 3,6%), p < 0,001. A maior proporção de óbitos no grupo 2 se manteve nos pacientes com 70-79 anos (p = 0,011), 80-89 anos (p ≤ 0,001) e > 90 anos (p ≤ 0,001). Os períodos pré-operatório e de permanência hospitalar foram maiores no grupo 2 em comparação ao grupo 1 (p ≤ 0,001). Conclusão: Este estudo demonstrou que o período pandêmico aumentou a taxa de mortalidade e o tempo pré-operatório e de internação em pacientes idosos com fratura do fêmur. Dessa forma, a pandemia tem afetado o atendimento das fraturas do fêmur proximal em idosos, o que reforça a necessidade da adoção de medidas de redução de complicações e mortalidade. Nível de Evidência II, Estudo Retrospectivo.

5.
Acta Ortop Bras ; 29(6): 293-296, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34849092

RESUMEN

OBJECTIVE: To determine the efficacy of Deep Venous Thrombosis (DVT) prophylaxis protocol in patients undergoing total hip arthroplasty (THA), and to verify differences in the rates of this complication when comparing primary replacement surgeries with revision surgeries. METHODS: We conducted a retrospective study of patients operated between 2012 and 2018, with inclusion and non-inclusion criteria determined by the researchers. A protocol was created to compile data including 92 patients, amounting to 110 operated hips, divided by gender, age, laterality, among other criteria. For THA cases, low molecular weight heparin chemoprophylaxis was used, associated with the use of pneumatic and elastic compression, concomitant to deambulation as soon as possible. The detection of DVT was determined by clinical evaluation and imaging exams such as: simple radiographs, ultrasound, arterial and venous color doppler, and laboratory tests. RESULTS: The use of the protocol was very effective in our study. Only one (1.09%) case of deep venous thrombosis was found. CONCLUSION: The use of thromboprophylaxis for DVT is indispensable, as was clearly demonstrated by these cases. We observed only one (1.09%) case of DVT in our series. Level of Evidence III, Retrospective Study.


OBJETIVO: Determinar a eficácia de protocolo de profilaxia contra a Trombose Venosa Profunda (TVP) em pacientes submetidos à artroplastia total do quadril (ATQ) e verificar diferenças nas taxas desta complicação ao comparar as cirurgias de substituição primária com as de revisão. MÉTODOS: Realizamos um estudo retrospectivo de pacientes operados entre 2012 e 2018, com critérios de inclusão e não inclusão determinados pelos pesquisadores. Foi criado um protocolo para a compilação de dados no qual foram incluídos 92 pacientes, estes com 110 quadris operados divididos por sexo, idade, lateralidade, entre outros critérios. Para os casos de ATQ, utilizamos a quimioprofilaxia com heparina de baixo peso molecular associada ao uso de compressão pneumática e elástica, concomitante à deambulação assim que possível. A detecção da TVP foi determinada pela avaliação clínica e por exames de imagem como: radiografias simples, exame ultrassonográfico, doppler colorido arterial e venoso e exames laboratoriais. RESULTADOS: A utilização do protocolo se mostrou bastante eficaz em nosso estudo. Foi encontrado apenas um (1,09%) caso de trombose venosa profunda. CONCLUSÃO: A utilização de tromboprofilaxia para a TVP é indispensável e consagrada nestes casos. Observamos apenas um (1,09%) caso de TVP em nossa casuística. Nível de Evidência III, Estudo Retrospectivo.

6.
Acta ortop. bras ; 29(6): 293-296, Nov.-Dec. 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1349898

RESUMEN

ABSTRACT Objective: To determine the efficacy of Deep Venous Thrombosis (DVT) prophylaxis protocol in patients undergoing total hip arthroplasty (THA), and to verify differences in the rates of this complication when comparing primary replacement surgeries with revision surgeries. Methods: We conducted a retrospective study of patients operated between 2012 and 2018, with inclusion and non-inclusion criteria determined by the researchers. A protocol was created to compile data including 92 patients, amounting to 110 operated hips, divided by gender, age, laterality, among other criteria. For THA cases, low molecular weight heparin chemoprophylaxis was used, associated with the use of pneumatic and elastic compression, concomitant to deambulation as soon as possible. The detection of DVT was determined by clinical evaluation and imaging exams such as: simple radiographs, ultrasound, arterial and venous color doppler, and laboratory tests. Results: The use of the protocol was very effective in our study. Only one (1.09%) case of deep venous thrombosis was found. Conclusion: The use of thromboprophylaxis for DVT is indispensable, as was clearly demonstrated by these cases. We observed only one (1.09%) case of DVT in our series. Level of Evidence III, Retrospective Study.


RESUMO Objetivo: Determinar a eficácia de protocolo de profilaxia contra a Trombose Venosa Profunda (TVP) em pacientes submetidos à artroplastia total do quadril (ATQ) e verificar diferenças nas taxas desta complicação ao comparar as cirurgias de substituição primária com as de revisão. Métodos: Realizamos um estudo retrospectivo de pacientes operados entre 2012 e 2018, com critérios de inclusão e não inclusão determinados pelos pesquisadores. Foi criado um protocolo para a compilação de dados no qual foram incluídos 92 pacientes, estes com 110 quadris operados divididos por sexo, idade, lateralidade, entre outros critérios. Para os casos de ATQ, utilizamos a quimioprofilaxia com heparina de baixo peso molecular associada ao uso de compressão pneumática e elástica, concomitante à deambulação assim que possível. A detecção da TVP foi determinada pela avaliação clínica e por exames de imagem como: radiografias simples, exame ultrassonográfico, doppler colorido arterial e venoso e exames laboratoriais. Resultados: A utilização do protocolo se mostrou bastante eficaz em nosso estudo. Foi encontrado apenas um (1,09%) caso de trombose venosa profunda. Conclusão: A utilização de tromboprofilaxia para a TVP é indispensável e consagrada nestes casos. Observamos apenas um (1,09%) caso de TVP em nossa casuística. Nível de Evidência III, Estudo Retrospectivo.

7.
Acta Ortop Bras ; 29(5): 246-248, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34629947

RESUMEN

OBJECTIVE: To date, the literature lacks consensus on the most efficient method to measure the range of motion of an in vitro prosthetic system. In this study, we propose the use of a relatively low-cost online software to measure the range of motion of hip prosthetic implants manufactured in Brazil and compare its results with the current technical standards for hip arthroplasty. METHODS: Three different diameters of femoral heads were evaluated (28 mm, 32 mm, and 36 mm). The mean values of the angular displacement of the prosthesis in each motion axis were obtained by computer simulations. RESULTS: The range of motion with each femoral head was 28mm (extension/flexion: 148°, internal/external rotation: 179°, adduction/abduction: 107°), 32 mm (152°/185°/114°), and 36 mm (158°/193°/120°). CONCLUSION: The computational method showed that the larger the femoral head, the greater the range of motion of the hip joint prosthetic system. Additional clinical studies are necessary to compare the physical results obtained with the values found in this study by computational modeling. Level of evidence V, Experimental study.


OBJETIVO: A maneira mais eficiente de se aferir a amplitude de movimento de um sistema protético in vitro ainda não é bem estabelecido na literatura. Assim, o presente estudo propõe a utilização de um software online de custo relativamente baixo para mensuração da amplitude de movimento de um conjunto protético nacional de quadril e comparar os resultados obtidos com a norma técnica vigente para as artroplastias de quadril. MÉTODOS: A avaliação foi realizada com três diferentes diâmetros de cabeças femorais (28 mm, 32 mm e 36 mm); os valores médios do deslocamento angular da prótese em cada eixo de movimento foram obtidos por meio de simulações computacionais no programa Autodesk Inventor. RESULTADOS: as amplitudes de movimento obtidas foram: cabeça 28mm (extensão/flexão: 148°, rotação interna/externa: 179°, adução/abdução: 107°), cabeça 32° (152°/185°/114°), cabeça 36° (158°/193°/120°). CONCLUSÃO: O método computacional utilizado no presente estudo possibilitou concluir que quanto maior a cabeça femoral, maior será a amplitude de movimento do sistema protético para articulação de quadril. Novos estudos clínicos, tanto pré quanto pós-operatórios, devem ser realizados para comparar os resultados físicos obtidos com os valores encontrados nesta avaliação por meio de modelo computacional. Nível de Evidência V, Estudo experimental.

8.
Acta ortop. bras ; 29(5): 246-248, Sept.-Oct. 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1339065

RESUMEN

ABSTRACT Objective: To date, the literature lacks consensus on the most efficient method to measure the range of motion of an in vitro prosthetic system. In this study, we propose the use of a relatively low-cost online software to measure the range of motion of hip prosthetic implants manufactured in Brazil and compare its results with the current technical standards for hip arthroplasty. Methods: Three different diameters of femoral heads were evaluated (28 mm, 32 mm, and 36 mm). The mean values of the angular displacement of the prosthesis in each motion axis were obtained by computer simulations. Results: The range of motion with each femoral head was 28mm (extension/flexion: 148°, internal/external rotation: 179°, adduction/abduction: 107°), 32 mm (152°/185°/114°), and 36 mm (158°/193°/120°). Conclusion: The computational method showed that the larger the femoral head, the greater the range of motion of the hip joint prosthetic system. Additional clinical studies are necessary to compare the physical results obtained with the values found in this study by computational modeling. Level of evidence V, Experimental study.


RESUMO Objetivo: A maneira mais eficiente de se aferir a amplitude de movimento de um sistema protético in vitro ainda não é bem estabelecido na literatura. Assim, o presente estudo propõe a utilização de um software online de custo relativamente baixo para mensuração da amplitude de movimento de um conjunto protético nacional de quadril e comparar os resultados obtidos com a norma técnica vigente para as artroplastias de quadril. Métodos: A avaliação foi realizada com três diferentes diâmetros de cabeças femorais (28 mm, 32 mm e 36 mm); os valores médios do deslocamento angular da prótese em cada eixo de movimento foram obtidos por meio de simulações computacionais no programa Autodesk Inventor. Resultados: as amplitudes de movimento obtidas foram: cabeça 28mm (extensão/flexão: 148°, rotação interna/externa: 179°, adução/abdução: 107°), cabeça 32° (152°/185°/114°), cabeça 36° (158°/193°/120°). Conclusão: O método computacional utilizado no presente estudo possibilitou concluir que quanto maior a cabeça femoral, maior será a amplitude de movimento do sistema protético para articulação de quadril. Novos estudos clínicos, tanto pré quanto pós-operatórios, devem ser realizados para comparar os resultados físicos obtidos com os valores encontrados nesta avaliação por meio de modelo computacional. Nível de Evidência V, Estudo experimental.

9.
Rev Bras Ortop (Sao Paulo) ; 55(5): 597-604, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33132462

RESUMEN

Objective This study aims to compare the in vitro wear rate of crosslinked, high molecular weight polyethylene coupled to 36-mm diameter ceramic heads and 32-mm diameter metal heads. Methods Ceramic-on-polyethylene (36 mm) and metal-on-polyethylene (32 mm) tribological pairs were submitted to biomechanical tests in a simulator to determine the wear rate after 15 × 10 6 cycles. Results A statistically significant difference ( p = 0.0005) was detected when comparing the wear rate of assemblies with metallic heads (average wear: 14.12 mg/MC) and ceramic heads (average wear: 7.46 mg/MC). Conclusion The present study demonstrated the lower wear rate in prosthetic assemblies using 36-mm crosslinked ceramic-on-polyethylene tribological pairs compared to 32-mm crosslinked metal-on-polyethylene assemblies. This finding demonstrates the effectiveness of ceramic-on-polyethylene tribological pairs, even with large diameter heads.

10.
Rev. bras. ortop ; 55(5): 597-604, Sept.-Oct. 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1144213

RESUMEN

Abstract Objective This study aims to compare the in vitro wear rate of crosslinked, high molecular weight polyethylene coupled to 36-mm diameter ceramic heads and 32-mm diameter metal heads. Methods Ceramic-on-polyethylene (36 mm) and metal-on-polyethylene (32 mm) tribological pairs were submitted to biomechanical tests in a simulator to determine the wear rate after 15 × 106 cycles. Results A statistically significant difference (p= 0.0005) was detected when comparing the wear rate of assemblies with metallic heads (average wear: 14.12 mg/MC) and ceramic heads (average wear: 7.46 mg/MC). Conclusion The present study demonstrated the lower wear rate in prosthetic assemblies using 36-mm crosslinked ceramic-on-polyethylene tribological pairs compared to 32-mm crosslinked metal-on-polyethylene assemblies. This finding demonstrates the effectiveness of ceramic-on-polyethylene tribological pairs, even with large diameter heads.


Resumo Objetivo: O objetivo do presente estudo foi comparar, in vitro, a taxa de desgaste do polietileno de alto peso molecular reticulado acoplado a cabeças cerâmicas de 36 mm de diâmetro e acoplado a cabeças metálicas de 32 mm de diâmetro. Métodos: Foram realizados ensaios biomecânicos em simulador de desgaste para os pares tribológicos cerâmica-poli (36 mm) e metal-poli (32 mm) a fim de verificar a taxa de desgaste após em 15 × 106 ciclos. Resultados: Na comparação entre as medidas de taxa de desgaste dos conjuntos com cabeças metálicas (média:14,12 mg/MC) e cerâmicas (média:7,46 mg/MC) houve diferença estatitsticamente significativa (p= 0,0005). Conclusão: O presente estudo demonstrou menor taxa de desgaste em conjuntos protéticos que utilizaram o par tribológico cerâmica-polietileno reticulado de 36 mm em comparação aos conjuntos com metal-polietileno reticulado de 32 mm. Tal achado demonstra a eficácia do par tribológico cerâmica-poli, mesmo com a utilização de cabeças de grande diâmetro.


Asunto(s)
Diseño de Prótesis , Pesos y Medidas , Técnicas In Vitro , Cerámica , Artroplastia de Reemplazo de Cadera , Polietileno , Cadera
11.
Rev Bras Ortop ; 52(Suppl 1): 3-13, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28971080

RESUMEN

While the value of national arthroplasty registries (NAR) for quality improvement in total hip arthroplasty (THA) has already been widely reported, some methodological limitations associated with observational epidemiological studies that may interfere with the assessment of safety and efficacy of prosthetic implants have recently been described in the literature. Among the main limitations of NAR, the need for at least 80% compliance of all health institutions covered by the registry is emphasized; completeness equal or greater than 90% of all THA performed; restricted data collection; use of revision surgery as the sole criterion for outcome; and the inability of establishing a definite causal link with prosthetic dysfunction. The present article evaluates the advantages and limitations of NAR, in the light of current knowledge, which point to the need for a broader data collection and the use of more structured criteria for defining outcomes. In this scenario, the authors describe of idealization, conceptual and operational structure, and the project of implantation and implementation of a multicenter registry model, called Rempro-SBQ, which includes healthcare institutions already linked to the Brazilian Hip Society (Sociedade Brasileira de Quadril [SBQ]). This partnership enables the collection of more reliable and comprehensive data at a higher hierarchical level, with a significant reduction in maintenance and financing costs. The quality improvement actions supported by SBQ may enhance its effectiveness and stimulate greater adherence for collecting, storing, interpreting, and disseminating information (feedback).


Ainda que os registros nacionais de artroplastias (RNAs) sejam um importante instrumento de controle e melhoria da qualidade da artroplastia total de quadril (ATQ), algumas limitações metodológicas associadas aos estudos epidemiológicos observacionais, que podem interferir na avaliação da segurança e eficácia dos implantes protéticos, têm sido recentemente descritas na literatura.Dentre as principais limitações destacam-se a necessidade de cobertura mínima de 80% das instituições hospitalares da região objeto do registro; integralidade mínima de 90% de todas as ATQs feitas; coleta de informações mais restritas; uso da cirurgia de revisão como critério único de desfecho e a dificuldade de se estabelecer um nexo causal com a disfunção protética.No presente artigo avaliamos as vantagens e limitações dos RNAs, à luz dos conhecimentos atuais, que apontam para a necessidade da coleta de informações mais amplas e de uso de critérios mais estruturados na definição de desfechos.Nesse cenário, descrevemos os processos de idealização, a estrutura conceitual e operacional e o projeto de implantação e implementação de um modelo de registro multicêntrico, denominado Rempro-SBQ, que inclui os centros hospitalares de treinamento em cirurgia de quadril já ligados institucionalmente à Sociedade Brasileira de Quadril (SBQ). Essa parceria possibilita, simultaneamente, a coleta de informações mais abrangentes e de elevado nível hierárquico, de forma confiável, com redução bastante significativa dos custos de manutenção e financiamento. As ações de melhoria da qualidade, amparadas pela SBQ, podem protagonizar uma condição de maior efetividade e maior adesão aos procedimentos de coleta, armazenamento, interpretação e divulgação das informações.

12.
Rev. bras. ortop ; 52(supl.1): 3-13, 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1042412

RESUMEN

Abstract While the value of national arthroplasty registries (NAR) for quality improvement in total hip arthroplasty (THA) has already been widely reported, some methodological limitations associated with observational epidemiological studies that may interfere with the assessment of safety and efficacy of prosthetic implants have recently been described in the literature. Among the main limitations of NAR, the need for at least 80% compliance of all health institutions covered by the registry is emphasized; completeness equal or greater than 90% of all THA performed; restricted data collection; use of revision surgery as the sole criterion for outcome; and the inability of establishing a definite causal link with prosthetic dysfunction. The present article evaluates the advantages and limitations of NAR, in the light of current knowledge, which point to the need for a broader data collection and the use of more structured criteria for defining outcomes. In this scenario, the authors describe of idealization, conceptual and operational structure, and the project of implantation and implementation of a multicenter registry model, called Rempro-SBQ, which includes healthcare institutions already linked to the Brazilian Hip Society (Sociedade Brasileira de Quadril [SBQ]). This partnership enables the collection of more reliable and comprehensive data at a higher hierarchical level, with a significant reduction in maintenance and financing costs. The quality improvement actions supported by SBQ may enhance its effectiveness and stimulate greater adherence for collecting, storing, interpreting, and disseminating information (feedback).


Resumo Ainda que os registros nacionais de artroplastias (RNAs) sejam um importante instrumento de controle e melhoria da qualidade da artroplastia total de quadril (ATQ), algumas limitações metodológicas associadas aos estudos epidemiológicos observacionais, que podem interferir na avaliação da segurança e eficácia dos implantes protéticos, têm sido recentemente descritas na literatura.Dentre as principais limitações destacam-se a necessidade de cobertura mínima de 80% das instituições hospitalares da região objeto do registro; integralidade mínima de 90% de todas as ATQs feitas; coleta de informações mais restritas; uso da cirurgia de revisão como critério único de desfecho e a dificuldade de se estabelecer um nexo causal com a disfunção protética.No presente artigo avaliamos as vantagens e limitações dos RNAs, à luz dos conhecimentos atuais, que apontam para a necessidade da coleta de informações mais amplas e de uso de critérios mais estruturados na definição de desfechos.Nesse cenário, descrevemos os processos de idealização, a estrutura conceitual e operacional e o projeto de implantação e implementação de um modelo de registro multicêntrico, denominado Rempro-SBQ, que inclui os centros hospitalares de treinamento em cirurgia de quadril já ligados institucionalmente à Sociedade Brasileira de Quadril (SBQ). Essa parceria possibilita, simultaneamente, a coleta de informações mais abrangentes e de elevado nível hierárquico, de forma confiável, com redução bastante significativa dos custos de manutenção e financiamento. As ações de melhoria da qualidade, amparadas pela SBQ, podem protagonizar uma condição de maior efetividade e maior adesão aos procedimentos de coleta, armazenamento, interpretação e divulgação das informações.


Asunto(s)
Falla de Prótesis , Sistema de Registros , Artroplastia de Reemplazo de Cadera
13.
Acta ortop. bras ; 24(6): 327-329, Nov.-Dec. 2016. tab, graf
Artículo en Portugués | LILACS | ID: biblio-827693

RESUMEN

ABSTRACT Objective: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. Methods: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck -shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. Results: Of the 101 measurements, an average of 130.9±6.7° was obtained, ranging from 112° to 150°. Correlating these measurements with epidemiological variables, only age was statistically significant. Conclusion: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. Level of Evidence III, Study of nonconsecutive patients; without consistently applied reference ''gold'' standard.

14.
Acta Ortop Bras ; 24(6): 327-329, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28924360

RESUMEN

OBJECTIVE: To assess the adequacy to the Brazilian population of orthopedic implants used for treatment of proximal femoral fractures. METHODS: The neck-shaft angle of the femur of 101 patients was measured in anteroposterior pelvis radiographs and these measurements were correlated to gender, age, height, weight and ethnicity. In addition, we compared the values of the neck -shaft angle with the angulation of the main implants available in the Brazilian market for the treatment of transtrochanteric fractures. RESULTS: Of the 101 measurements, an average of 130.9±6.7° was obtained, ranging from 112° to 150°. Correlating these measurements with epidemiological variables, only age was statistically significant. CONCLUSION: Most of the analyzed population presented anatomical characteristics that allow the proper use of these implants to treat transtrochanteric fractures, as indicated from the analysis of neck-shaft angles. Nonetheless, 4% of individuals did not fit this pattern and would have required alternative implants. Level of Evidence III, Study of nonconsecutive patients; without consistently applied reference ''gold'' standard.

15.
Rev Bras Ortop ; 50(4): 462-8, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26417570

RESUMEN

Gluteal pain is a frequent symptom in athletes, and defining it etiologically is a challenge for orthopedists. In the present study, using an anatomical approach to the posterior region of the pelvis and the proximal femur, divided into four quadrants, systematized investigation is proposed with the aim of optimizing the treatment and accelerating athletes' return to their sport, through correct diagnosis.


A dor glútea é um sintoma frequente em atletas. Sua definição etiológica é um desafio para o ortopedista. No presente estudo, os autores propõem, por meio de uma abordagem anatômica da região posterior da pelve e do fêmur proximal, dividida em quatro quadrantes, a investigação sistematizada do local, visando, por meio do diagnóstico correto, a aperfeiçoar o tratamento e acelerar o retorno do atleta ao esporte.

16.
Rev. bras. ortop ; 48(4): 374-376, ago. 2013. graf
Artículo en Inglés | LILACS | ID: lil-690269

RESUMEN

OBJECTIVE: The overuse injuries in the hip joint occur commonly in sports practitioners and currently due to technical advances in diagnostic imaging, especially magnetic resonance imaging (MRI), are often misdiagnosed. Recently, a group of people were reported, all female, with pain and swelling in the pelvic region.T2-weighted MRI showed increased signal in the enthesis of the iliotibial band (ITB) along the lower border of the iliac tubercle. We report a case of a 34 year old woman, non-professional runner, with pain at the iliac crest with no history of trauma and whose MRI was compatible with the proximal iliotibial band syndrome. .


As lesões por sobrecarga na articulação do quadril ocorrem comumente em praticantes de esporte e atualmente, por causa do avanço das técnicas de diagnóstico por imagem, especialmente a ressonância magnética (RM), são frequentemente diagnosticadas. Recentemente, foi estudado um grupo de pacientes, todos do sexo feminino, com quadro de dor e edema na região do tubérculo ilíaco. A RM ponderada em T2 demonstrava aumento de sinal na êntese da banda iliotibial (BIT) ao longo da margem inferior do tubérculo ilíaco. Relatamos um caso de uma mulher de 34 anos, corredora não profissional, com quadro de dor na crista ilíaca sem história de trauma e cuja RM era compatível com a síndrome da banda iliotibial proximal. .


Asunto(s)
Humanos , Femenino , Adulto Joven , Cadera , Ilion , Imagen por Resonancia Magnética , Dolor
17.
Rev Bras Ortop ; 48(4): 374-376, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-31304136

RESUMEN

The overuse injuries in the hip joint occur commonly in sports practitioners and currently due to technical advances in diagnostic imaging, especially magnetic resonance imaging (MRI), are often misdiagnosed. Recently, a group of people were reported, all female, with pain and swelling in the pelvic region. T2-weighted MRI showed increased signal in the enthesis of the iliotibial band (ITB) along the lower border of the iliac tubercle. We report a case of a 34 year old woman, non-professional runner, with pain at the iliac crest with no history of trauma and whose MRI was compatible with the proximal iliotibial band syndrome.


As lesões por sobrecarga na articulação do quadril ocorrem comumente em praticantes de esporte e atualmente, por causa do avanço das técnicas de diagnóstico por imagem, especialmente a ressonância magnética (RM), são frequentemente diagnosticadas. Recentemente, foi estudado um grupo de pacientes, todos do sexo feminino, com quadro de dor e edema na região do tubérculo ilíaco. A RM ponderada em T2 demonstrava aumento de sinal na êntese da banda iliotibial (BIT) ao longo da margem inferior do tubérculo ilíaco. Relatamos um caso de uma mulher de 34 anos, corredora não profissional, com quadro de dor na crista ilíaca sem história de trauma e cuja RM era compatível com a síndrome da banda iliotibial proximal.

18.
Rev. bras. ortop ; 47(2): 165-168, mar.-abr. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-643092

RESUMEN

OBJETIVOS: Avaliar a eficácia da osteossíntese de fraturas do colo femoral com dois em vez de três parafusos. MÉTODOS: Avaliadas, retrospectivamente, 39 fraturas, divididas em grupos nos quais foram utilizados dois (n = 28) parafusos paralelos e três parafusos (n = 11) na configuração de triângulo invertido segundo a técnica AO. Os pacientes foram acompanhados até o desfecho: consolidação ou falha. RESULTADOS: No grupo em que se utilizou dois parafusos, observamos consolidação em 23 das 28 fraturas (82%). No grupo de três parafusos observou-se consolidação em seis das 11 fraturas (55%). Não houve diferença estatística entre os valores obtidos. CONCLUSÃO: Não houve diferença no prognóstico dessas fraturas quando tratadas com dois parafusos paralelos ou três parafusos em triângulo invertido segundo a técnica AO-ASIF. Mais estudos são necessários para estabelecer conclusão definitiva.


OBJECTIVES: To evaluate the efficacy of osteosynthesis on femoral neck fractures using two instead of three screws. METHODS: Thirtynine fractures were retrospectively evaluated, divided into groups in which two screws were used in parallel (n = 28) or three screws (n =11) in an inverted triangle configuration (in accordance with the AO technique). The patients were then followed up until reaching the outcome of either consolidation or failure. RESULTS: In the group in which two screws were used, consolidation was observed in 23 of the 28 fractures (82%). In the group in which three screws were used, consolidation was observed in 6 of the 11 fractures (55%). There was no statistically significant difference between these percentages. CONCLUSION: There was no difference in the prognosis for these fractures when treated using two screws in parallel or three screws in an inverted triangle in accordance with the AO technique. Further studies are needed in order to establish a definitive conclusion.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Anciano de 80 o más Años , Tornillos Óseos , Fracturas del Cuello Femoral/rehabilitación , Fracturas del Cuello Femoral/terapia
19.
Rev Bras Ortop ; 47(2): 165-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-27042616

RESUMEN

OBJECTIVES: To evaluate the efficacy of osteosynthesis on femoral neck fractures using two instead of three screws. METHODS: Thirty-nine fractures were retrospectively evaluated, divided into groups in which two screws were used in parallel (n = 28) or three screws (n =11) in an inverted triangle configuration (in accordance with the AO technique). The patients were then followed up until reaching the outcome of either consolidation or failure. RESULTS: In the group in which two screws were used, consolidation was observed in 23 of the 28 fractures (82%). In the group in which three screws were used, consolidation was observed in 6 of the 11 fractures (55%). There was no statistically significant difference between these percentages. CONCLUSION: There was no difference in the prognosis for these fractures when treated using two screws in parallel or three screws in an inverted triangle in accordance with the AO technique. Further studies are needed in order to establish a definitive conclusion.

20.
Rev Bras Ortop ; 47(6): 780-3, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-27047901

RESUMEN

An association between hip pain and quadratus femoris muscle abnormality on magnetic resonance imaging (MRI) with concurrent narrowing of the ischiofemoral space has been reported in the recent literature. This raises the possibility that the muscle damage observed is due to ischiofemoral impingement. This diagnosis has been noted in middle-aged females either with or without a history of trauma or surgery, is a rarely described feature. We report here on a 31-year-old woman who presented with non-traumatic hip pain and evidence of narrowing of the ischiofemoral space and edema in the quadratus femoris. Nonsurgical treatment was administered, which relieved her hip pain. The diagnosis of ischiofemoral impingement should be considered in female patients complaining of hip pain without any other evident cause.